VS - Vertical Spray Deaerator (Single Vertical Tank)
Kansas City Deaerator Spray deaerators provide an ecomical alternative to tray type units. The units feature a simple, trouble-free, quiet design and are designed for constant loads.
Incoming undeaerated water enters the Deaerator through spring-loaded, stainless steel spray valves. These variable orifice valves produce a fine spray in a uniform pattern from 5% to 200% of design.
The fine droplets of water maximize the surface area in contact with steam, raising the temperature to within a few degrees of saturation temperature and instantly releasing the majority of the corrosive, non-condensable gases. The preheated and partially deaerated water is channeled through a collection basin downcomer, through a tortuous path second stage deoxygenator. Here the hottest, purest steam vigorously scrubs the water to heat it to the saturation temperature and strips the last traces of dissolved gases.
The steam and non-condensables flow upward into the stainless steel vent condensing area where the steam is condensed with the inlet water and the gases are released to atmosphere through the vent outlet. The deaerated water then falls to the storage area.
Features
Selection Chart
10 Minutes Storage
Deaerator Model
(no pumps) |
Deaerator Model
(w/pumps) |
Boiler
Capacity (HP) |
Rated
Capacity (#/HR) |
Storage to
Overflow (Gallons) |
Storage
Capacity (minutes) |
Water
Inlet ‘A’ (in) |
Steam
Inlet ‘B’ (in) |
Empty
Weight (lbs) |
Operate
Weight (lbs) |
Flooded
Weight (lbs) |
Price
|
---|---|---|---|---|---|---|---|---|---|---|---|
290
|
10,000
|
210
|
10
|
1
|
3
|
1,300
|
3,000
|
4,000
|
Call
|
||
580
|
20,000
|
420
|
10
|
1.5
|
6
|
1,700
|
5,000
|
7,000
|
Call
|
||
725
|
25,000
|
525
|
10
|
2
|
6
|
2,100
|
7,000
|
9,000
|
Call
|
||
870
|
30,000
|
630
|
10
|
2
|
6
|
2,400
|
8,000
|
12,000
|
Call
|
||
1,159
|
40,000
|
840
|
10
|
2
|
6
|
2,700
|
10,000
|
14,000
|
Call
|
||
1,449
|
50,000
|
1,050
|
10
|
2.5
|
8
|
3,100
|
12,000
|
17,000
|
Call
|
||
1,739
|
60,000
|
1,260
|
10
|
2.5
|
8
|
3,300
|
14,000
|
20,000
|
Call
|
||
2,029
|
70,000
|
1,470
|
10
|
3
|
8
|
3,600
|
16,000
|
23,000
|
Call
|
||
2,319
|
80,000
|
1,680
|
10
|
3
|
10
|
4,000
|
18,000
|
25,000
|
Call
|
||
2,609
|
90,000
|
1,890
|
10
|
3
|
10
|
4,400
|
20,000
|
29,000
|
Call
|
||
3,188
|
110,000
|
2,310
|
10
|
4
|
10
|
5,100
|
24,000
|
34,000
|
Call
|
||
3,768
|
130,000
|
2,730
|
10
|
4
|
12
|
5,900
|
29,000
|
40,000
|
Call
|
5 Minutes Storage
Deaerator Model
(no pumps) |
Deaerator Model
(w/pumps) |
Boiler
Capacity (HP) |
Rated
Capacity (#/HR) |
Storage to
Overflow (Gallons) |
Storage
Capacity (minutes) |
Water
Inlet ‘A’ (in) |
Steam
Inlet ‘B’ (in) |
Empty
Weight (lbs) |
Operate
Weight (lbs) |
Flooded
Weight (lbs) |
Price
|
---|---|---|---|---|---|---|---|---|---|---|---|
VS-3006-020 (PKG)
|
290
|
10,000
|
210
|
10
|
1
|
3
|
1,300
|
3,000
|
4,000
|
Call
|
|
580
|
20,000
|
420
|
10
|
1.5
|
6
|
1,700
|
5,000
|
7,000
|
Call
|
||
725
|
25,000
|
525
|
10
|
2
|
6
|
2,100
|
7,000
|
10,000
|
Call
|
||
870
|
30,000
|
630
|
10
|
2
|
6
|
2,400
|
8,000
|
12,000
|
Call
|
||
1,159
|
40,000
|
840
|
10
|
2
|
6
|
2,700
|
10,000
|
15,000
|
Call
|
||
1,449
|
50,000
|
1,050
|
10
|
2.5
|
8
|
3,100
|
12,000
|
18,000
|
Call
|
||
1,739
|
60,000
|
1,260
|
10
|
2.5
|
8
|
3,300
|
14,000
|
21,000
|
Call
|
||
VS-6009-140 (PKG)
|
2,029
|
70,000
|
1,470
|
10
|
3
|
8
|
3,600
|
16,000
|
23,000
|
Call
|
|
VS-6009-140 (PKG)
|
2,319
|
80,000
|
1,680
|
10
|
3
|
10
|
4,000
|
18,000
|
26,000
|
Call
|
|
VS-6009-140 (PKG)
|
2,609
|
90,000
|
1,890
|
10
|
3
|
10
|
4,400
|
20,000
|
30,000
|
Call
|
|
VS-6009-140 (PKG)
|
3,188
|
110,000
|
2,310
|
10
|
4
|
10
|
5,100
|
24,000
|
35,000
|
Call
|
|
VS-6009-140 (PKG)
|
3,768
|
130,000
|
2,730
|
10
|
4
|
12
|
5,900
|
29,000
|
41,000
|
Call
|
***Deaerator Models w/ pumps displayed in red are “Consult Factory” items***
Accessories
ITEM
|
DESCRIPTION
|
ACC PKG
|
PUMP PKG
|
√
Select |
---|---|---|---|---|
A
|
WATER INLET | |||
A1
|
Inlet Valve | |||
Mechanical |
STD
|
STD
|
||
Pneumatic |
OPT
|
OPT
|
||
A2
|
Level Controller |
STD
|
STD
|
|
Level Transmitter |
OPT
|
OPT
|
||
A3
|
Inlet Valve Bypass Valves |
OPT
|
STD
|
|
A4
|
Inlet Valve Bypass Piping |
OPT
|
STD
|
|
A5
|
Inlet Valve Bypass Strainer |
OPT
|
STD
|
|
B
|
STEAM CONTROL | |||
B1
|
Steam PRV |
OPT
|
||
Self Contained |
OPT
|
OPT
|
||
Pneumatic |
OPT
|
OPT
|
||
B2
|
Steam PRV Controller |
OPT
|
OPT
|
|
B3
|
Steam PRV Bypass Valves |
OPT
|
OPT
|
|
B4
|
Steam PRV Bypass Piping |
OPT
|
OPT
|
|
B5
|
Steam PRV Bypass Strainer |
OPT
|
OPT
|
|
C
|
RELIEF VALVE | |||
C1
|
Relief Valve | |||
Sentinel |
STD
|
STD
|
||
Full |
OPT
|
OPT
|
||
C2
|
Relief Valve Exhaust Piping |
OPT
|
OPT
|
|
D
|
THERMOMETER | |||
D1
|
(2) 5″ Thermometer w/ss wells |
STD
|
STD
|
|
E
|
PRESSURE GAUGE | |||
E1
|
(1) 4 1/2″ Pressure Gauge |
STD
|
STD
|
|
E2
|
Siphon & Cock |
STD
|
STD
|
|
E3
|
Pressure Transmitter |
OPT
|
OPT
|
|
F
|
VENT | |||
F1
|
Vent Valve |
STD
|
STD
|
|
F2
|
Vent Orifice w/ Flange |
OPT
|
OPT
|
|
F3
|
Vent Bypass Valves |
OPT
|
OPT
|
|
F4
|
Vent Bypass Piping |
OPT
|
OPT
|
|
H
|
VACUUM BREAKER | |||
H1
|
Vacuum Breaker |
STD
|
STD
|
ITEM
|
DESCRIPTION
|
ACC PKG
|
PUMP PKG
|
√
Select |
---|---|---|---|---|
M
|
BFP RECIRC | |||
M1
|
BFP Recirc Shutoff |
N/A
|
OPT
|
|
M2
|
BFP Recirc Check |
N/A
|
OPT
|
|
M3
|
BFP Recirc Orifice |
N/A
|
OPT
|
|
BFP Recirc ARC Valve |
N/A
|
OPT
|
||
M4
|
BFP Recirc Piping |
N/A
|
OPT
|
|
M5
|
BFP Recirc Pressure Gauge |
N/A
|
OPT
|
|
N
|
BFP SUCTION | |||
N1
|
BF Pumps | |||
(2) 100% Capacity |
N/A
|
STD
|
||
(3) 50% Capacity |
N/A
|
OPT
|
||
Motors | ||||
ODP |
N/A
|
STD
|
||
TEFC |
N/A
|
OPT
|
||
N2
|
BFP Suction Isolation Valve
|
N/A
|
STD
|
|
N3
|
BFP Suction Strainer
|
N/A
|
STD
|
|
N4
|
BFP Suction Piping
|
N/A
|
STD
|
|
N5
|
BFP Suction Expansion Joint
|
N/A
|
STD
|
|
N6
|
BFP Discharge Pressure Gauge
|
N/A
|
OPT
|
|
N7
|
BFP Discharge Check Valve
|
N/A
|
OPT
|
|
N8
|
BFP Discharge Isolation Valve
|
N/A
|
OPT
|
|
O
|
CHEMICAL FEED
|
|||
O
|
Chemical Feed Quill
|
OPT
|
OPT
|
|
Q
|
OVERFLOW
|
|||
Q1
|
Overflow Valve/Trap
|
STD
|
STD
|
|
Q3
|
Overflow Piping
|
OPT
|
STD
|
|
R
|
LEVEL SWITCHES
|
|||
R1
|
Level Switches
|
|||
High and Low (TWO) |
STD
|
STD
|
||
High High (ADDITIONAL) |
OPT
|
OPT
|
||
R2
|
Level Switch Bridle Piping
|
OPT
|
OPT
|
|
S
|
GAUGE GLASS
|
|||
S1
|
Gauge Glass
|
|||
Red Line Pyrex |
STD
|
STD
|
||
Reflex |
OPT
|
OPT
|
||
Magnetic |
OPT
|
OPT
|
||
S2
|
Gauge Glass Bridle
|
OPT
|
STD
|