Accessories
 

Kansas City Deaerator can provide accessories to complete the deaerator as a turnkey system. Typical systems include pressure and temperature monitoring, level control, pressure control, boiler feed pumps, boiler feed pump recirculation and control panels. Mechanical, pneumatic or electronic accessories can be utilized to interface with existing plant control systems.

 
 
 
Relief Valve
 
Relief Valve
Relief Valve
One or more relief valves are provided to either protect the pressure vessel against over-pressurization or act as sentinel relief. Overpressure can occur upon a failure of the steam pressure reducing valve, single or multiple trap discharges entering the deaerator or other conditions. It is the responsibility of the purchaser to evaluate all possible conditions and determine the worst case scenario for sizing the relief valve. If sentinel relief is selected by the customer for the deaerator, safety relief must be provided elsewhere in the system. When sentinel relief is selected, a nominally sized sentinel relief valve will be provided unless HEI is specified, in which case, sizing will be per HEI standards. The relief valve(s) are set to relieve at the deaerator design pressure.
Relief Valve
       
 
Pressure Gauge
 
Pressure Gauge

A pressure gauge is provided for the steam space in the deaerator. A typical gauge would be 4 ½” dial (minimum) type with stainless steel bourdon tube construction. Either dry or liquid filled gauges may be specified. A siphon tube and shutoff cock for mounting the pressure gauge is included. In addition to considering the operating pressure of the deaerator, the gauge resolution (graduations) should be evaluated when selecting the pressure range of the pressure gauge.

       
 
Thermometer
 
Thermometer

Thermometers, when properly located, give a visual indication of deaerator performance. Preferred locations are the steam space of the deaerator, and under the water level in the storage area. Gauges are 5” dial (minimum) bimetal with stainless steel thermowells. Gauges should be constructed with adjustable viewing angle, hermetically sealed and with a stem length consistent with the location of the gauge in the deaerator. In addition to consideration of the operating temperature of the deaerator, the gauge resolution (graduations) should be evaluated when selecting the temperature range of the thermometer.

       
 
Control Valves
 
Mechanical Valve
Control Valves are typically used to control the inlet water flow from one or more sources. The valve size depends on the required flow rate, temperature, and valve inlet and outlet pressures. The valve shall be modulating type with stainless steel trim and can be specified as mechanical, pneumatic or electronic. An external float cage and lever actuator are provided for a mechanically operated valve. For pneumatic control, a pneumatic actuator and caged displacer level controller are provided. If electronic control is specified, provide an I/P positioner on the valve to accepting a 4-20 ma input and a level transmitter are specified required.
Valve and Actuator
       
 
Level Switches
 
Level Switch

Level switches are utilized for warning of high or low water levels , actuating a pneumatic overflow valve, and/or for boiler feedpump cutoff. Audible or visible alarms may be specified if desired. As a minimum the switches shall have the following characteristics:

 
Housings will be general purpose NEMA-1
 
Switch ratings shall be 10 amps 120 VAC/DC
 
Switch action shall be SPST
 
Other housings, ratings, and actions may be specified
 
Mercury or non-mercury switches may be specified
       
 
Overflow Valves
 
Overflow Valve

Overflow control valves are used to protect against high water level in the storage area. This device can be a float trap or a control valve with control sized to relieve the full capacity of deaerator .

       
 
Gauge Glass
 
Reflex Gauge
Gauge glasses are used to visually indicate the liquid level in the storage tank . The glass consists of a water column with shutoff valves to cover 10%-90% of the water level in the storage section. Glass can be specified as tubular red line pyrex, reflex or magnetic type. The gauge glass should be rated for the operating temperature and pressure of the deaerator
 
Red Line Pyrex Gauge
Magnetic Gauge
       
 
Other Instruments and Accessories
 
Level Controller

In addition to those shown here, Kansas City Deaerator can provide a wide variety of transmitters, controllers and other items. Consult with the factory for specialized applications.

Pneumatic Valve
   
Accessories Chart
ITEM
DESCRIPTION
ACC PKG
PUMP PKG

Select
A
WATER INLET
     
A1
Inlet Valve
-
-
-
-
Mechanical
STD
STD
-
-
Pneumatic
OPT
OPT
-
A2
Level Controller
STD
STD
-
-
Level Transmitter
OPT
OPT
-
A3
Inlet Valve Bypass Valves
OPT
STD
-
A4
Inlet Valve Bypass Piping
OPT
STD
-
A5
Inlet Valve Bypass Strainer
OPT
STD
-
B
STEAM CONTROL
     
B1
Steam PRV
-
OPT
-
-
Self Contained
OPT
OPT
-
-
Pneumatic
OPT
OPT
-
B2
Steam PRV Controller
OPT
OPT
-
B3
Steam PRV Bypass Valves
OPT
OPT
-
B4
Steam PRV Bypass Piping
OPT
OPT
-
B5
Steam PRV Bypass Strainer
OPT
OPT
-
C
RELIEF VALVE
     
C1
Relief Valve
-
-
-
-
Sentinel
STD
STD
-
-
Full
OPT
OPT
-
C2
Relief Valve Exhaust Piping
OPT
OPT
-
D
THERMOMETER
     
D1
(2) 5" Thermometer w/ss wells
STD
STD
-
E
PRESSURE GAUGE
     
E1
(1) 4 1/2" Pressure Gauge
STD
STD
-
E2
Siphon & Cock
STD
STD
-
E3
Pressure Transmitter
OPT
OPT
-
F
VENT
     
F1
Vent Valve
STD
STD
-
F2
Vent Orifice w/ Flange
OPT
OPT
-
F3
Vent Bypass Valves
OPT
OPT
-
F4
Vent Bypass Piping
OPT
OPT
-
H
VACUUM BREAKER
     
H1
Vacuum Breaker
STD
STD
-
ITEM
DESCRIPTION
ACC PKG
PUMP PKG

Select
M
BFP RECIRC
     
M1
BFP Recirc Shutoff
N/A
OPT
-
M2
BFP Recirc Check
N/A
OPT
-
M3
BFP Recirc Orifice
N/A
OPT
-
-
BFP Recirc ARC Valve
N/A
OPT
-
M4
BFP Recirc Piping
N/A
OPT
-
M5
BFP Recirc Pressure Gauge
N/A
OPT
-
N
BFP SUCTION
     
N1
BF Pumps
-
-
-
-
(2) 100% Capacity
N/A
STD
-
-
(3) 50% Capacity
N/A
OPT
-
-
Motors
-
-
-
-
ODP
N/A
STD
--
-
TEFC
N/A
OPT
--
N2
BFP Suction Isolation Valve
N/A
STD
--
N3
BFP Suction Strainer
N/A
STD
-
N4
BFP Suction Piping
N/A
STD
-
N5
BFP Suction Expansion Joint
N/A
STD
-
N6
BFP Discharge Pressure Gauge
N/A
OPT
-
N7
BFP Discharge Check Valve
N/A
OPT
-
N8
BFP Discharge Isolation Valve
N/A
OPT
-
O
CHEMICAL FEED
     
O
Chemical Feed Quill
OPT
OPT
-
Q
OVERFLOW
     
Q1
Overflow Valve/Trap
STD
STD
-
Q3
Overflow Piping
OPT
STD
-
R
LEVEL SWITCHES
     
R1
Level Switches
-
-
-
-
High and Low (TWO)
STD
STD
-
-
High High (ADDITIONAL)
OPT
OPT
-
R2
Level Switch Bridle Piping
OPT
OPT
-
S
GAUGE GLASS
     
S1
Gauge Glass
--
--
--
-
Red Line Pyrex
STD
STD
-
-
Reflex
OPT
OPT
-
-
Magnetic
OPT
OPT
-
S2
Gauge Glass Bridle
OPT
STD
-
 